EPC B deadline

Private rented buildings over 1,000 m² · England and Wales

Which large let buildings fall short of EPC B?

42,869 non-domestic buildings over 1,000 m² with evidence of being let hold a valid EPC. 25,735 of them (60.0%) are rated below B.

79,274,757 m² of 141,226,437 m² (56.1%) is rated below EPC B.

The gap is smaller than it looks

11,628 of the below-B buildings were rated before the methodology changed on 15 June 2022. When large buildings like these have been re-assessed since, 75.1% of electrically heated ones and 29.9% of gas-heated ones came back at B or better. Applied to today’s stock, that is about 5,329 buildings that are below B on paper only. See the calculation.

By region

Regions and nations
AreaLet buildings over 1,000 m²Below EPC BFloorspace below BBelow B on paper*
East Midlands 3,412 2,168 57.3% ≈402
East of England 4,057 2,401 54.9% ≈499
London 6,319 3,412 51.9% ≈858
North East 2,143 1,280 56.9% ≈266
North West 5,852 3,573 56.4% ≈724
South East 6,338 3,685 56.2% ≈781
South West 3,788 2,283 58.9% ≈436
Wales 1,979 1,261 63.1% ≈258
West Midlands 4,875 3,182 59.8% ≈640
Yorkshire and The Humber 4,106 2,490 53.6% ≈464

* Calculated: below-B buildings on pre-June-2022 certificates expected to come back at B or better on re-assessment. Method.

All councils · Download the figures